Up to 2000 events can be retrieved from the event memory based on various criteria. Customer texts can be adapted directly on the operating unit of the control panel or with the Cerberus-Engineering-Tool software. All detector lines are monitored for ground faults. The control panel and the fire detection system are custom-configured using the Cerberus-Engineering-Tool software. The control panel may be used as a standalone unit or networked. You will find details of system networking in product data sheet A6V A6V _i_en_ĥ Function features The FC722 is a compact fire control panel with integrated operating unit for processing signals from FD720 devices. A maximum of 64 stations is supported in total. Siemens Danger Management System Ethernet D元750+ FT724/FC72x Matrix printer RS232 FC722 Cluster (C-WEB/SAFEDLINK) In-/ Outputs 6 stations FC722/FC724 Repeater FN A6V _i_en_Ĥ An optical Ethernet network (C-WEB/LAN) allows up to 4 clusters with up to 6 stations to be operated on one network. If the cluster is connected to a danger management system via BACnet, up to 6 control panels and terminals can be networked. 252 addresses HI720 FDCI22 OH720 stub line FDM22 Mimic display input FT200-A FDCW24 FDCL22 OP720 OP720 4 outputs FDM273 Transmission of an alarm signal Transmission of a fault signal via FCI2007-A Fire controls via FCI2008-A Conventional horn line via FCI2009-A FDCIO222 4 inputs FDOOT27 Radio detectors FDA22/ FDA24 FC0 or XC0 Fire detection or Extinguishing control unit collective 2 A6V _i_en_ģ Networking of several fire control panels Up to 32 control panels and terminals can be linked to form a cluster (C- WEB/SAFEDLINK network).
2 in-/outputs optionally FDCIO223 C-NET 2 (4) loops max. possible FDS22/ FDS229 FDCI222 HI722 FDCI723 4 inputs DBS720 OH720 output FDCIO22 FDM22x Detection line collective Siemens, TM Synova SynoLINE300 or SynoLINE600 FDCL22-Ex DBS72 / DBS729 input 24VDC ext.
1 FC722 Cerberus PRO Fire control panel FS720 series, IP6 Compact, pre-assembled, microprocessor-controlled fire control panel with integrated operating unit for up to 252 addresses Fire control panel can be used as a standalone version or can be networked Up to 64 stations, such as control panels and terminals, can be linked to form a network Integrated degraded mode function Redundant network node, degraded mode operation according to EN 54 Fast Ethernet interface for a heterogeneous network Integrated user-friendly operating unit Can be extended by adding printer, key switches, LED indicators Slots for RS232 and RS485 serial interfaces Emergency power supply for emergency operating time of up to 72 hours Detection and automatic reading in (auto-configuration) of all C-NET devices, ready for operation immediately Processes signals from Cerberus PRO FD720 detector series Floor repeater displays, floor repeater operating units, and alarm devices on C- NET detector line Flexible configuration of complex applications and controls Configuration data can be uploaded/downloaded via remote access Firmware for all processor-controlled control panel components can be updated A6V _i_en_ Control Products and SystemsĢ System overview FC722 Repeater FN2002 Cluster (C-WEB/SAFEDLINK) FC722 Fire control panel FT724 Remote access Engineering Tool, Operating Tool FDM233-Ex Explosionhazard area OOH740-A9-Ex FT200/FT20 Floor repeater terminal / Floor repeater display 24VDC ext.